We recently put a sculpture on our roof: Gilroy, or “Mr Hydrogen.” It’s a larger version of a creepy face sculpture I’d made some moths ago. Like it, and my saber-toothed tiger, the eyes follow you. A worry about this version: is there enough keeping it from blowing down on the cars? Anyone who puts up a large structure must address this worry, but I’m a professional engineer with a PhD from Princeton, so my answer is a bit different from most.
The main force on most any structure is the wind (the pyramids are classic exceptions). Wind force is generally proportional to the exposed area and to the wind-speed squared: something called form-drag or quadratic drag. Since force is related to wind-speed, I start with some good statistics for wind speed, shown in the figure below for Detroit where we are.
The highest Detroit wind speeds are typically only 16 mph, but every few years the winds are seen to reach 23 mph. These are low relative to many locations: Detroit has does not get hurricanes and rarely gets tornadoes. Despite this, I’ve decided to brace the sculpture to withstand winds of 50 mph, or 22.3 m/s. On the unlikely chance there is a tornado, I figure there would be so much other flotsam that I would not have to answer about losing my head. (For why Detroit does not get hurricanes or tornadoes, see here. If you want to know why tornadoes lift things, see here).
The maximum area Gilroy presents is 1.5 m2. The wind force is calculated by multiplying this area by the kinetic energy loss per second 1/2ρv2, times a form factor. F= (Area)*ƒ* 1/2ρv2, where ρ is the density of air, 1.29Kg/m3, and v is velocity, 22.3 m/s. The form factor, ƒ, is about 1.25 for this shape: ƒ is found to be 1.15 for a flat plane, and 1.1 to 1.3 a rough sphere or ski-jumper. F = 1.5*1.25* (1/2 *1.29*22.32) = 603 Nt = 134 lb.; pressure is this divided by area. Since the weight is only about 40 lbs, I find I have to tie down the sculpture. I’ve done that with a 150 lb rope, tying it to a steel vent pipe.
It is possible that there’s a viscous lift force too, but it is likely to be small given the blunt shape and the flow Reynolds number: 3190. There is also the worry that Gilroy might fall apart from vibration. Gilroy is made of 3/4″ plywood, treated for outdoor use and then painted, but the plywood is held together with 25 steel screws 4″ long x 1/4″ OD. Screws like this will easily hold 134 lbs of steady wind force, but a vibrating wind will cause fatigue in the metal (bend a wire often enough and it falls apart). I figure I can leave Gilroy up for a year or so without worry, but will then go up to replace the screws and check if I have to bring him/ it down.
In the meantime, I’ll want to add a sign under the sculpture: “REB Research, home of Mr Hydrogen” I want to keep things surreal, but want to be safe and make sales.
by Robert E. Buxbaum, June 21, 2013
Pingback: Physics of no fear, no fall ladders | REB Research Blog
Do you have a photograph of the mounting/fastening system? How did you account for corrosion?